InReach DataCenter Specs:

Datacenter Features and Benefits

  • Redundant Tier 1 bandwidth providers
  • Scalable custom bandwidth hookups
  • Redundant back-up power infrastructure
  • Climate control
  • Redundant security and access
  • Secure rack space
  • 24 x 7 network monitoring
  • 24 x 7 emergency help
  • Reliable and onsite technical help
  • Work area and lounge with wireless/wired hotspot, large work table, and computer carts

Colocation Redundant Back Up Power Infrastructure

  • 1,000 to 1,600 amps at 480 volt total capacity, depending on site
  • 80 to 85 watts per square foot including HVAC
  • 120/208 V AC and -48 V DC available
  • 100% generator backup
  • Generator capacity 600-2000 KW
  • Size of fuel tank 1,000 to 2,000 gallons
  • Generator - both auto start and auto transfer - Isolation bypass feature on automatic transfer switch
  • Minimum 24-hour run time fuel capacity - 2-hour response for fuel delivery
  • UPS backup power system
  • Voltage output 480 transformed to 120/208 V
  • 48 volt DC battery plant
  • 1200 amp expandable to 4800 amp
  • 2-hour battery reserve non-redundant, 4 hours redundant
  • A/B power feeds available
  • Grounding in accordance with NFPA 70

Colocation Redundant Security and Monitoring

  • 24/7 security management via the Security Operations Center (SOC)
  • Remote camera monitoring 24/7, backed by digital recordings on file for 45 days
  • Access to equipment area 24/7 days via card key and pass code only
  • Escort services 24/7 at sites with non-secured equipment areas
  • Locking cabinets and/or cages
  • Full CCTV surveillance

Colocation Climate Control

  • 80 to 85 watts per square foot including HVAC
  • Cooling not less than 150 BTU/h per square foot with an N+1 redundancy
  • Temperature is maintained at 72 degrees F dry bulb at ASHRAE 1%
  • Redundant power supplied to HVAC systems by diesel generators if there is a power interruption
  • 30% to 60% humidity non-condensing. Humidity control delivered through ATS/Liebert units via infra-red humidifier

Colocation Facility Features

  • Open space for cabinets
  • Private cages available
  • Meet all code specifications for safety and electrical grounding, per NFPA 70
  • Open, accessible ceiling
  • DC power and communication cabling tray pathways
  • Optical fiber guide conveyance system
  • Heavy load freight elevators or loading dock access to the space
  • Comprehensive and flexible cabling infrastructure